Vehicle, tire & car seat recalls

Gillig Low Floor recalled over fire hazard

Recall date
December 23, 2016
Source
National Highway Traffic Safety Administration (NHTSA)
Official notice title
Gillig, LLC recalls 2015–2016 Gillig Low Floor
Recall number
16V931000
Brand / firm
Gillig
Sold / distributed
Potentially affected: 451 units

Why it was recalled

If not corrected, the fire suppression systems on certain CNG-powered buses may fail to indicate the presence of a natural gas (methane) leak. In such cases, the driver will not receive a fault code indicating that the Gas Detection electronics have been disabled. This may increase the risk of asphyxiation, fire, or explosion.

What was recalled

Gillig LLC (Gillig) is recalling certain model year 2015-2016 Low Floor compressed natural gas (CNG) transit buses manufactured September 1, 2015, to December 5, 2016, equipped with Amerex SafetyNet fire suppression system panel/controller units. These buses have gas detection electronics that may be disabled without providing the operator with a warning of a system malfunction. Affected display panel/controller units were also provided as replacement parts for warranty claims, part numbers 16389, 24109, 24918, 24926 and 24927.

What to do

Gillig will notify owners, and Amerex representatives will replace the Operator Display Panel/Controllers, free of charge. The recall began January 20, 2017. Owners may contact Gillig customer service at 1-800-735-1500.. Follow the official notice for full instructions.

Read the official recall notice →

Get recall alerts

Free email alert whenever Gillig has a new recall — straight from official government data. Unsubscribe anytime.

More recalls from: Gillig